蘇州阿爾法生物實驗器材有限公司

瓊脂糖預染預制膠說明書

*運輸及保存
*Shipping and Storage
瓊脂糖預染預制膠電泳試劑盒的小黑盒 2~8℃保存和運輸,有效期 12 個月。
Ship and store the kit at 2~8℃. It will remain stable for one year.
專适 6×DNA Loading Buffer 2~8℃運輸,長期需要-20℃保存,有效期 12 個月。
Ship Optimized 6×DNA loading buffer at 2~8℃,for short-time storage and at -20℃ for long-time storage. It will remain stable for one year.
TAE 速溶顆粒 2~8℃或常溫運輸,常溫保存,有效期 24 個月。
Ship TAE Instant Granule at 2~8℃ or room temperature and store at room temperature. It will remain stable for two years.
專适 Marker 2~8℃運輸,長期需要-20℃保存,有效期 12 個月。
Ship Optimized Marker at 2~8℃ and store it at -20°C for long-time storage. It will remain stable for one year.
*自備試劑
*Reagents Required But Not Provided
核酸樣品、去離子水
Nucleic acid sample and Deionized water
*使用方法
*Procedure
1.量取約 600ml 的蒸餾水加入燒杯,并放置一個磁性攪拌子于燒杯中。将燒杯置于磁力攪拌器上,慢慢加入 1 袋 TAE 速溶顆粒的全部内容物,攪拌溶液直至完全
溶解。把燒杯中的溶液倒入 1000ml 的容量瓶中,再加入蒸餾水,定容至 1000ml,即爲 1×TAE 溶液。
1. Add one pouch of TAE Instant Granule into the cleaned beaker, dissolved completely with 600 ml distilled water under a magnetic stirrer. Pour the solution into 1L flask. Add distilled water to the
solution until the total volume is 1L. The final solution is 1×TAE buffer.
2.取出一塊獨立包裝的瓊脂糖預染預制膠,撕掉表面的塑料膜,反轉包裝,用兩手的食指和中指托住塑料殼邊緣,開口向下沒入電泳液中,然後用兩個大拇指輕
輕按壓塑料殼背面中心部分,瓊脂糖預染預制膠就會落入電泳液中,此時的預制膠帶孔面向上,移動膠塊,使孔側端靠近電泳槽負極。如樣品孔内有氣泡,應設法除
去。
2. Take out one kit, take off the plastic package, reverse it, support the two edges with index and middle fingers of both hands, immerse it in the buffer with the opening downward and gently press the
central part of the kit with two thumbs. Thus the gel will fall into the buffer with the side of the well upward. Move the gel to make the well end close to negative electrode of the electrophoresis cell. If
bubbles are produced in the sample wells, try to remove them.
3.按 5:1 的比例取适量核酸樣品和專适 6×DNA Loading Buffer 混勻,用移液器将專适 Marker 和樣品混合液依次緩慢加入被浸沒的凝膠加樣孔内。
3. Mix Optimized 6×DNA loading buffer and DNA sample at a volume ratio of 1:5. Carefully load prepared Marker and the mixed sample into the wells with pipette successively.
4.接通電源,紅色爲正極,黑色爲負極,切記 DNA 樣品由負極往正極泳動(靠近加樣孔的一端爲負)。
4. Connect the electrophoresis cell to the power source according to the conventions: Red-Anode and Black-Cathode. Turn on the power source. Note that the DNA sample moves from the negative to
the positive (the end near the wells that DNA samples are loaded in is negative).
5.根據指示劑泳動的位置,判斷是否終止電泳。
5. Determine whether to stop electrophoresis according to the migration of the tracking dyes.
6.電泳完畢,關閉電源,用凝膠成像儀觀察電泳條帶及其位置,與 Marker 比較擴增産物的大小。
6. Switch off the power source when the electrophoresis finishes. Visualize the band by using a gel documentation system and compare the size of the amplified product with that of Marker

預制膠取較操作方法


蛋白預制膠取膠方法

蘇州阿爾法生物實驗器材有限公司2008年紮根蘇州生物醫藥産業園,作爲蘇州本地深耕18年的實驗室儀器設備專業供應商,始終以「品質爲基、服務爲本」爲核心經營理念,專注爲蘇州及長三角地區高校、藥企、醫院、第三方檢測機構提供高品質實驗室儀器設備、試劑耗材及本地化專屬服務。

【品質保障·層層嚴選】公司擁有梅特勒瑞甯、知楚、天能、朗基、恒爾、海爾生物、天根生化、耐思、賽默飛等海内外一線廠商授權,所有産品均爲原廠直供,具備完整質檢報告、醫療器械注冊證、校準證書等合規資質,嚴格符合GMP、CNAS實驗室标準。

   核心儀器設備均通過ISO9001質量體系認證,試劑耗材遵循嚴格冷鏈倉儲标準,從源頭杜絕質量隐患,确保實驗數據準确可靠。

    【本地服務·極速響應】- 蘇州本地倉儲:自建大型恒溫恒濕倉儲中心,常規儀器耗材常備上萬種現貨,蘇州地區當日達,江浙滬次日達,緊急訂單可4小時内送達- 

專屬技術團隊:15+持證儀器工程師團隊,提供2小時響應、12小時上門的本地化售後服務,涵蓋安裝調試、計量校準、故障維修、定期維保全流程- 

提供專屬儀器選型方案,配套實驗技術培訓,解決客戶從采購到應用的全流程痛點- 

增值服務:免費樣機試用、樣品申領、設備移機、軟件升級等本地化專屬服務,不用對接外地供應商,溝通高效、售後無憂

【深耕蘇州·口碑見證】

18年來累計服務蘇州本地1000+實驗室,包括蘇州大學、中科院納米所、信達生物、藥明康德等知名機構,憑借穩定的産品品質和高效的本地化服務,成爲蘇州生物醫藥産業圈内口碑卓著的實驗室設備供應商。蘇州及周邊地區實驗室儀器采購、設備維保、耗材配套,歡迎撥打本地服務熱線0512-62956104,或18934597460 /18020269905,我們将爲您提供實驗室設備一站式解決方案。